- Last Update: 2023-01-14 11:25:27
- Preferred: Yes
- Start time: 12/12/2015 00:00:00
- End time: 12/12/2015 04:00:00
- Noise variability type:
ANTHROPIC
- Frequency range min: 0.1
- Frequency range max: 15
- Band instrument: HH
- Note: The station is located in a booth of a hydroelectric power station. There are several disturbances, the strongest of which is between 8 and 8.5 Hz, mainly during the months February, March, April 2015: disturbances cause a very narrow trough at about 8 Hz and sometimes a peak between 10 and 14 Hz.
-
Picture rotated ratio:
Picture ratio: